增广智能 - 领先的精密运动控制系统及元件提供商

回到首页
RM-NPLA-HF
SoftForce® Micro Platform-type Linear Actuator
RM-NPLA-HF SoftForce® Micro Platform-type Linear Actuator

How to Order

Product Specifications

Product Model and Parameters ( Applicable Sensor Range for HF50, HF100, HF200 )

 
Model RM-NPLA-10-30-1-HF RM-NPLA-10-30-2-HF RM-NPLA-10-30-4-HF RM-NPLA-10-30-6-HF
Size Code 10 10 10 10
Weight (kg) 0.7 0.7 0.7 0.7
Dimensions (mm) 156.5*35*48 156.5*35*48 156.5*35*48 156.5*35*48
Stroke (mm) 30 30 30 30
Lead (mm) 1 2 4 6
Max.speed (mm/s) 50 100 200 300
Max. load Mass - Horizontal(kg) 2 2 2 1.5
Max. load Mass - Vertical(kg) 3 2 1 0.75
Repeat Positioning Accuracy(mm) ±0.005 ±0.005 ±0.005 ±0.005
Compatible Controllers RM-CEUF,
RM-CEMF
RM-CEUF,
RM-CEMF
RM-CEUF,
RM-CEMF
RM-CEUF,
RM-CEMF
Supporting Bus Protocols Modbus RTU, EtherCAT, Modbus TCP, PROFINET, EtherNet/IP, CC-LINK, CANopen
Supporting Control Modes I/O, Pulse Control (Excluding RM-CEMF-55 Controller)
Rated Voltage (V) DC24±10% DC24±10% DC24±10% DC24±10%
Rated Current (A) 1.25 1.25 1.25 1.25
Cable Length (m) 3/5 3/5 3/5 3/5
Usage Environment 0~40°C, < 85%RH(Non-condensing) 0~40°C, < 85%RH(Non-condensing) 0~40°C, < 85%RH(Non-condensing) 0~40°C, < 85%RH(Non-condensing)
Protection Class IP IP40 IP40 IP40 IP40

 

 
Model RM-NPLA-10-50-1-HF RM-NPLA-10-50-2-HF RM-NPLA-10-50-4-HF RM-NPLA-10-50-6-HF
Size Code 10 10 10 10
Weight (kg) 0.8 0.8 0.8 0.8
Dimensions (mm) 176*35*48 176*35*48 176*35*48 176*35*48
Stroke (mm) 50 50 50 50
Lead (mm) 1 2 4 6
Max.speed (mm/s) 50 100 200 300
Max. load Mass - Horizontal(kg) 2 2 2 1.5
Max. load Mass - Vertical(kg) 3 2 1 0.75
Repeat Positioning Accuracy(mm) ±0.005 ±0.005 ±0.005 ±0.005
Compatible Controllers RM-CEUF,
RM-CEMF
RM-CEUF,
RM-CEMF
RM-CEUF,
RM-CEMF
RM-CEUF,
RM-CEMF
Supporting Bus Protocols Modbus RTU, EtherCAT, Modbus TCP, PROFINET, EtherNet/IP, CC-LINK, CANopen
Supporting Control Modes I/O, Pulse Control (Excluding RM-CEMF-55 Controller)
Rated Voltage (V) DC24±10% DC24±10% DC24±10% DC24±10%
Rated Current (A) 1.25 1.25 1.25 1.25
Cable Length (m) 3/5 3/5 3/5 3/5
Usage Environment 0~40°C, < 85%RH(Non-condensing) 0~40°C, < 85%RH(Non-condensing) 0~40°C, < 85%RH(Non-condensing) 0~40°C, < 85%RH(Non-condensing)
Protection Class IP IP40 IP40 IP40 IP40

 

Product Model and Parameters ( Applicable Sensor Range for HF10 )

 
Model RM-NPLA-10-30-2-HF10 RM-NPLA-10-30-4-HF10 RM-NPLA-10-30-6-HF10 RM-NPLA-10-50-2-HF10 RM-NPLA-10-50-4-HF10 RM-NPLA-10-50-6-HF10
Size Code 10 10 10 10 10 10
Weight (kg) 0.7 0.7 0.7 0.8 0.8 0.8
Dimensions (mm) 133.5*35*48 133.5*35*48 133.5*35*48 153.5*35*48 153.5*35*48 153.5*35*48
Stroke (mm) 30 30 30 50 50 50
Lead (mm) 2 4 6 2 4 6
Max.speed (mm/s) 100 200 300 100 200 300
Max. load Mass - Horizontal(kg) 0.5 0.5 0.5 0.5 0.5 0.5
Max. load Mass - Vertical(kg) 0.5 0.3 0.3 0.5 0.3 0.3
Repeat Positioning Accuracy(mm) ±0.005 ±0.005 ±0.005 ±0.005 ±0.005 ±0.005
Compatible Controllers RM-CEUF,
RM-CEMF
RM-CEUF,
RM-CEMF
RM-CEUF,
RM-CEMF
RM-CEUF,
RM-CEMF
RM-CEUF,
RM-CEMF
RM-CEUF,
RM-CEMF
Supporting Bus Protocols Modbus RTU, EtherCAT, Modbus TCP, PROFINET, EtherNet/IP, CC-LINK, CANopen
Supporting Control Modes I/O, Pulse Control (Excluding RM-CEMF-55 Controller)
Rated Voltage (V) DC24±10% DC24±10% DC24±10% DC24±10% DC24±10% DC24±10%
Rated Current (A) 1.25 1.25 1.25 1.25 1.25 1.25
Cable Length (m) 3/5 3/5 3/5 3/5 3/5 3/5
Usage Environment 0~40℃ ,< 85%RH (Non-condensing)
Protection Class IP IP40 IP40 IP40 IP40 IP40 IP40

 

Product Model and Parameters ( Applicable Sensor Range for HF50, HF100, HF200,HF300 )

 
Model RM-NPLA-16-75-5-HF RM-NPLA-16-75-10-HF RM-NPLA-16-150-5-HF RM-NPLA-16-150-10-HF
Size Code 16 16 16 16
Weight (kg) 1.6 1.6 2.2 2.2
Dimensions (mm) 209*58*63.5 209*58*63.5 282*58*63.5 282*58*63.5
Stroke (mm) 75 75 150 150
Lead (mm) 5 10 5 10
Max.speed (mm/s) 250 380 250 380
Max. load Mass - Horizontal(kg) 3 3 3 3
Max. load Mass - Vertical(kg) 5 3 5 3
Repeat Positioning Accuracy(mm) ±0.02 ±0.02 ±0.02 ±0.02
Compatible Controllers RM-CEUF,
RM-CEMF
RM-CEUF,
RM-CEMF
RM-CEUF,
RM-CEMF
RM-CEUF,
RM-CEMF
Supporting Bus Protocols Modbus RTU, EtherCAT, Modbus TCP, PROFINET, EtherNet/IP, CC-LINK, CANopen
Supporting Control Modes I/O, Pulse Control (Excluding RM-CEMF-55 Controller)
Rated Voltage (V) DC24±10% DC24±10% DC24±10% DC24±10%
Rated Current (A) 5 5 5 5
Cable Length (m) 3/5 3/5 3/5 3/5
Usage Environment 0~40℃ ,< 85%RH (Non-condensing)
Protection Class IP IP40 IP40 IP40 IP40

 

Closed-Loop Output Range Table for Different Sensor Ranges

Lead  (mm) Stroke(mm) Closed-loop Output Range(N)
HF10-0001 HF50-001 HF100-005 HF200-010 HF300-050
1 30、50 / 0.2~49.8 0.6~99.4 1.1~198.9 /
2 30、50 0.02~9.98 0.2~49.8 0.6~99.4 / /
4 30、50 0.02~9.98 0.2~49.8 / / /
6 30、50 0.02~9.98 0.2~29.8 / / /
5 75、150 / 0.2~49.8 0.6~99.4 1.1~198.9 5.1~294.9
10 75、150 / 0.2~49.8 0.6~99.4 1.1~178.9 /



Description

The drawings provided in this Catalog are for the default standard model. If you require other models with different motor directions, outlet directions, or outlet methods, please contact your local sales representative to obtain the drawings for the optional models.

Documentation Download

Dimension Drawing
Model Image