增广智能 - 领先的精密运动控制系统及元件提供商

回到首页
RM-NPLA-HF
SoftForce® Micro Platform-type Linear Actuator
RM-NPLA-HF SoftForce® Micro Platform-type Linear Actuator

How to Order

Product Specifications

Product Model and Parameters ( Applicable Sensor Range for HF50, HF100, HF200 )

 
Model RM-NPLA-10-30-1-HF RM-NPLA-10-30-2-HF RM-NPLA-10-30-4-HF RM-NPLA-10-30-6-HF
Size Code 10 10 10 10
Weight 0.7 kg 0.7 kg 0.7 kg 0.7 kg
Dimensions 156.5*35*48 mm 156.5*35*48 mm 156.5*35*48 mm 156.5*35*48 mm
Stroke 30 mm 30 mm 30 mm 30 mm
Lead 1 mm 2 mm 4 mm 6 mm
Max. Speed  50 mm/s 100 mm/s 200 mm/s 300 mm/s
Max. Load Mass (Horizontal) 2 kg 2 kg 2 kg 1.5 kg
Max. Load Mass (Vertical) 3 kg 2 kg 1 kg 0.75 kg
Repeatability ±0.005 mm ±0.005 mm ±0.005 mm ±0.005 mm
Compatible Controllers RM-CEUF; RM-CEMF RM-CEUF; RM-CEMF RM-CEUF; RM-CEMF RM-CEUF; RM-CEMF
Bus Protocols RM-CEUF controller supports: EtherCAT; Modbus RTU; I/O
RM-CEMF controller supports: Modbus TCP; PROFINET; CC-LINK; Modbus RTU
Operating Voltage DC24 ±10% V DC24 ±10% V DC24 ±10% V DC24 ±10% V
Rated Current 1.25 A 1.25 A 1.25 A 1.25 A
Operating Environment 0–40°C, <85% RH
(non-condensing)
0–40°C, <85% RH
(non-condensing)
0–40°C, <85% RH
(non-condensing)
0–40°C, <85% RH
(non-condensing)
Protection Class IP40 IP40 IP40 IP40
Usage Environment 0~40°C, < 85%RH(Non-condensing) 0~40°C, < 85%RH(Non-condensing) 0~40°C, < 85%RH(Non-condensing) 0~40°C, < 85%RH(Non-condensing)
Protection Class IP IP40 IP40 IP40 IP40

 

 
 
Model RM-NPLA-10-50-1-HF RM-NPLA-10-50-2-HF RM-NPLA-10-50-4-HF RM-NPLA-10-50-6-HF
Size Code 10 10 10 10
Weight 0.8 0.8 0.8 0.8
Dimensions 176*35*48 mm 176*35*48 mm 176*35*48 mm 176*35*48 mm
Stroke 50 mm 50 mm 50 mm 50 mm
Lead 1 mm 2 mm 4 mm 6 mm
Max. Speed  50 mm/s 100 mm/s 200 mm/s 300 mm/s
Max. Load Mass (Horizontal) 2 kg 2 kg 2 kg 1.5 kg
Max. Load Mass (Vertical) 3 kg 2 kg 1 kg 0.75 kg
Repeatability ±0.005 mm ±0.005 mm ±0.005 mm ±0.005 mm
Compatible Controllers RM-CEUF; RM-CEMF RM-CEUF; RM-CEMF RM-CEUF; RM-CEMF RM-CEUF; RM-CEMF
Bus Protocols RM-CEUF controller supports: EtherCAT; Modbus RTU; I/O
RM-CEMF controller supports: Modbus TCP; PROFINET; CC-LINK; Modbus RTU
Operating Voltage DC24 ±10% V DC24 ±10% V DC24 ±10% V DC24 ±10% V
Rated Current 1.25 A 1.25 A 1.25 A 1.25 A
Operating Environment 0–40°C, <85% RH
(non-condensing)
0–40°C, <85% RH
(non-condensing)
0–40°C, <85% RH
(non-condensing)
0–40°C, <85% RH
(non-condensing)
Protection Class IP40 IP40 IP40 IP40
Usage Environment 0~40°C, < 85%RH(Non-condensing) 0~40°C, < 85%RH(Non-condensing) 0~40°C, < 85%RH(Non-condensing) 0~40°C, < 85%RH(Non-condensing)
Protection Class IP IP40 IP40 IP40 IP40

 

Product Model and Parameters ( Applicable Sensor Range for HF10 )

 
Model RM-NPLA-10-30-2-HF10 RM-NPLA-10-30-4-HF10 RM-NPLA-10-30-6-HF10 RM-NPLA-10-50-2-HF10 RM-NPLA-10-50-4-HF10 RM-NPLA-10-50-6-HF10
Size Code 10 10 10 10 10 10
Weight 0.7 kg 0.7 kg 0.7 kg 0.8 kg 0.8 kg 0.8 kg
Dimensions 133.5*35*48 mm 133.5*35*48 mm 133.5*35*48 mm 153.5*35*48 mm 153.5*35*48 mm 153.5*35*48 mm
Lead 2 mm 4 mm 6 mm 2 mm 4 mm 6 mm
Stroke 30 mm 30 mm 30 mm 50 mm 50 mm 50 mm
Max. Speed  100 mm/s 200 mm/s 300 mm/s 100 mm/s 200 mm/s 300 mm/s
Max. Load Mass (Horizontal) 0.5 kg 0.5 kg 0.5 kg 0.5 kg 0.5 kg 0.5 kg
Max. Load Mass (Vertical) 0.5 kg 0.3 kg 0.3 kg 0.5 kg 0.3 kg 0.3 kg
Repeatability ±0.005 mm ±0.005 mm ±0.005 mm ±0.005 mm ±0.005 mm ±0.005 mm
Compatible Controllers RM-CEUF; RM-CEMF
Bus Protocols RM-CEUF controller supports: EtherCAT; Modbus RTU; I/O
RM-CEMF controller supports: Modbus TCP; PROFINET; CC-LINK; Modbus RTU
Operating Voltage DC24 ±10% DC24 ±10% DC24 ±10% DC24 ±10% DC24 ±10% DC24 ±10%
Rated Current 1.25 1.25 1.25 1.25 1.25 1.25
Operating Environment 0–40°C, <85% RH (non-condensing)
Protection Class IP40 IP40 IP40 IP40 IP40 IP40
Usage Environment 0~40℃ ,< 85%RH (Non-condensing)
Protection Class IP IP40 IP40 IP40 IP40 IP40 IP40

 

Product Model and Parameters ( Applicable Sensor Range for HF50, HF100, HF200,HF300 )

 
 
Model RM-NPLA-16-75-5-HF RM-NPLA-16-75-10-HF RM-NPLA-16-150-5-HF RM-NPLA-16-150-10-HF
Size Code 16 16 16 16
Weight 1.6 kg 1.6 kg 2.2 kg 2.2 kg
Dimensions 209*58*63.5 mm 209*58*63.5 mm 282*58*63.5 mm 282*58*63.5 mm
Stroke 75 mm 75 mm 150 mm 150 mm
Lead 5 mm 10 mm 5 mm 10 mm
Max. Speed  250 mm/s 380 mm/s 250 mm/s 380 mm/s
Max. Load Mass (Horizontal) 3 kg 3 kg 3 kg 3 kg
Max. Load Mass (Vertical) 5 kg 3 kg 5 kg 3 kg
Repeatability ±0.02 mm ±0.02 mm ±0.02 mm ±0.02 mm
Compatible Controllers RM-CEUF; RM-CEMF RM-CEUF; RM-CEMF RM-CEUF; RM-CEMF RM-CEUF; RM-CEMF
Bus Protocols RM-CEUF controller supports: EtherCAT; Modbus RTU; I/O
RM-CEMF controller supports: Modbus TCP; PROFINET; CC-LINK; Modbus RTU
Operating Voltage DC24 ±10% V DC24 ±10% V DC24 ±10% V DC24 ±10% V
Rated Current 5 A 5 A 5 A 5 A
Operating Environment 0–40°C, <85% RH (non-condensing)
Protection Class IP40 IP40 IP40 IP40
Usage Environment 0~40℃ ,< 85%RH (Non-condensing)
Protection Class IP IP40 IP40 IP40 IP40

 

Closed-Loop Output Range Table for Different Sensor Ranges

Lead Stroke Closed-loop Output Range
HF10-0001 HF50-001 HF100-005 HF200-010 HF300-050
1 mm 30; 50 mm / 0.2 - 49.8 N 0.6 - 99.4 N 1.1 - 198.9 N /
2 mm 30; 50 mm 0.02 - 9.98 N 0.2 - 49.8 N 0.6 - 99.4 N / /
4 mm 30; 50 mm 0.02 - 9.98 N 0.2 - 49.8 N / / /
6 mm 30; 50 mm 0.02 - 9.98 N 0.2 - 29.8 N / / /
5 mm 75; 150 mm / 0.2 - 49.8 N 0.6 - 99.4 N 1.1 - 198.9 N 5.1 - 294.9 N
10 mm 75; 150 mm / 0.2 - 49.8 N 0.6 - 99.4 N 1.1 - 178.9 N /



Description

The drawings provided in this Catalog are for the default standard model. If you require other models with different motor directions, outlet directions, or outlet methods, please contact your local sales representative to obtain the drawings for the optional models.

Documentation Download

Dimension Drawing
Model Image