Product Model and Specifications - Split Type Model (External Controller)
![]() |
![]() |
![]() |
![]() |
|
| Model | RM-NPLA-10-30-1 | RM-NPLA-10-30-2 | RM-NPLA-10-30-4 | RM-NPLA-10-30-6 |
| Size Code | 10 | 10 | 10 | 10 |
| Weight (kg) | 0.5 | 0.5 | 0.5 | 0.5 |
| Dimensions (mm) | 111.5*34*48 | 111.5*34*48 | 111.5*34*48 | 111.5*34*48 |
| Stroke (mm) | 30 | 30 | 30 | 30 |
| Lead (mm) | 1 | 2 | 4 | 6 |
| Max.speed (mm/s) | 50 | 100 | 200 | 300 |
| Max. pushing Force (N) | 210 | 110 | 50 | 30 |
| Max. Horizontal load Mass (kg) | 6 | 3 | 2 | 1 |
| Max. Vertical load Mass (kg) | 3 | 2 | 1 | 0.5 |
| Repeat Positioning Accuracy (mm) | ±0.005 | ±0.005 | ±0.005 | ±0.005 |
| Permissible Load Torque (N.m) | MP: 9.75, MR: 11.31, MY: 3.75 | MP: 9.75, MR: 11.31, MY: 3.75 | MP: 9.75, MR: 11.31, MY: 3.75 | MP: 9.75, MR: 11.31, MY: 3.75 |
| Compatible Controllers | RM-CEU, RM-CEM | RM-CEU, RM-CEM | RM-CEU, RM-CEM | RM-CEU, RM-CEM |
| Supporting Bus Protocols | Modbus RTU, EtherCAT, Modbus TCP, PROFINET, EtherNet/IP, CC-LINK, CANopen | |||
| Rated Voltage (V) | DC24±10% | DC24±10% | DC24±10% | DC24±10% |
| Rated Current (A) | 1.25 | 1.25 | 1.25 | 1.25 |
| Cable Length (m) | 3/5 | 3/5 | 3/5 | 3/5 |
| Usage Environment | 0~40°C, < 85%RH (Non-condensing) | |||
| Protection Class IP | IP40 | IP40 | IP40 | IP40 |
![]() |
![]() |
![]() |
![]() |
|
| Model | RM-NPLA-10-50-1 | RM-NPLA-10-50-2 | RM-NPLA-10-50-4 | RM-NPLA-10-50-6 |
| Size Code | 10 | 10 | 10 | 10 |
| Weight (kg) | 0.6 | 0.6 | 0.6 | 0.6 |
| Dimensions (mm) | 131.5*34*48 | 131.5*34*48 | 131.5*34*48 | 131.5*34*48 |
| Stroke (mm) | 50 | 50 | 50 | 50 |
| Lead (mm) | 1 | 2 | 4 | 6 |
| Max.speed (mm/s) | 50 | 100 | 200 | 300 |
| Max. pushing Force (N) | 210 | 110 | 50 | 30 |
| Max. Horizontal load Mass (kg) | 6 | 3 | 2 | 1.5 |
| Max. Vertical load Mass (kg) | 3 | 2 | 1 | 0.5 |
| Repeat Positioning Accuracy (mm) | ±0.005 | ±0.005 | ±0.005 | ±0.005 |
| Permissible Load Torque (N.m) | MP: 9.75, MR: 11.31, MY: 3.75 | MP: 9.75, MR: 11.31, MY: 3.75 | MP: 9.75, MR: 11.31, MY: 3.75 | MP: 9.75, MR: 11.31, MY: 3.75 |
| Compatible Controllers | RM-CEU, RM-CEM | RM-CEU, RM-CEM | RM-CEU, RM-CEM | RM-CEU, RM-CEM |
| Supporting Bus Protocols | Modbus RTU, EtherCAT, Modbus TCP, PROFINET, EtherNet/IP, CC-LINK, CANopen | |||
| Rated Voltage (V) | DC24±10% | DC24±10% | DC24±10% | DC24±10% |
| Rated Current (A) | 1.25 | 1.25 | 1.25 | 1.25 |
| Cable Length (m) | 3/5 | 3/5 | 3/5 | 3/5 |
| Usage Environment | 0~40°C, < 85%RH (Non-condensing) | |||
| Protection Class IP | IP40 | IP40 | IP40 | IP40 |
![]() |
![]() |
![]() |
![]() |
|
| Model | RM-NPLA-16-75-5 | RM-NPLA-16-75-10 | RM-NPLA-16-150-5 | RM-NPLA-16-150-10 |
| Size Code | 16 | 16 | 16 | 16 |
| Weight (kg) | 1.4 | 1.4 | 1.9 | 1.9 |
| Dimensions (mm) | 164*58*63.5 | 164*58*63.5 | 237*58*63.5 | 237*58*63.5 |
| Stroke (mm) | 75 | 75 | 150 | 150 |
| Lead (mm) | 5 | 10 | 5 | 10 |
| Max.speed (mm/s) | 250 | 380 | 250 | 380 |
| Max. pushing Force (N) | 360 | 180 | 360 | 180 |
| Max. Horizontal load Mass (kg) | 18 | 15 | 18 | 15 |
| Max. Vertical load Mass (kg) | 6 | 3 | 6 | 3 |
| Repeat Positioning Accuracy (mm) | ±0.02 | ±0.02 | ±0.02 | ±0.02 |
| Power Failure Auto-Lock | Optional Brake | Optional Brake | Optional Brake | Optional Brake |
| Permissible Load Torque (N.m) | MP:18.13, MR:19.11, MY:18.13 | MP:18.13, MR:19.11, MY:18.13 | MP:18.13, MR:19.11, MY:18.13 | MP:18.13, MR:19.11, MY:18.13 |
| Compatible Controllers | RM-CEU, RM-CEM | RM-CEU, RM-CEM | RM-CEU, RM-CEM | RM-CEU, RM-CEM |
| Supporting Bus Protocols | Modbus RTU, EtherCAT, Modbus TCP, PROFINET, EtherNet/IP, CC-LINK, CANopen | |||
| Rated Voltage (V) | DC24±10% | DC24±10% | DC24±10% | DC24±10% |
| Rated Current (A) | 5 | 5 | 5 | 5 |
| Usage Environment | 0~40°C, < 85%RH (Non-condensing) | |||
| Protection Class IP | IP40 | IP40 | IP40 | IP40 |